BOD EVO Sensor System 6
BOD EVO Snesor
DataBox
BODSoft
Cat. No.
S10230146, BOD EVO Sensor System 6 °ßÀû¿äû

¿ë±â³» »ê¼ÒÀÇ ¹Ì¼¼ÇÑ ¾Ð·Âº¯È­¸¦ ÃøÁ¤ÇÏ´Â ¹æ½Ä (Manometric Method) À» ÀÌ¿ëÇÏ¿© ¿ëÁ¸»ê¼ÒÀÇ ¼Ò¸ð·®À» ºü¸£°í, Æí¸®ÇÏ°í, Á¤È®ÇÏ°Ô ÃøÁ¤Çϴ ȹ±âÀûÀÎ ½Å±â¼úÀÇ »ý¹°È­ÇÐÀû»ê¼Ò¿ä±¸·® (BOD, Biochemical Oxygen Demand) ºÐ¼® Àåºñ

BOD EVO Sensor ¿¡ ÀåÂøµÈ WiFi ½Ã½ºÅÛÀ» ÀÌ¿ëÇØ ¿ë±â³»ÀÇ BOD °ªÀÌ ½Ç½Ã°£À¸·Î ÄÄÇ»ÅÍ ¼ÒÇÁÆ®¿þ¾î·Î Àü¼ÛµÇ´Â ±â´ÉÀ» °¡Áø ¸ðµ¨


Wireless Data Transfering
Wireless Data Transferring ±â´ÉÀ» °¡Áø BOD EVO Sensor ¿¡ ÀÇÇØ ¿ë±â³» BOD °ªÀÌ ½Ç½Ã°£À¸·Î DataBox ·Î ¹«¼± Àü¼ÛµÇ¾î ÀÌ µ¥ÀÌÅÍ°ªÀÌ ÄÄÇ»ÅÍÀÇ BODSoft ÇÁ·Î±×·¥¿¡ ½Ç½Ã°£À¸·Î ³ªÅ¸³ª´Â ±â´ÉÀ» °¡Áø BOD ÃøÁ¤ ÀåÄ¡
Manometric Method
300ml ¿ë±â³»¿¡¼­ ¹Ì»ý¹°¿¡ ÀÇÇØ ¿ëÁ¸»ê¼Ò°¡ ¼Ò¸ðµÇ¸é
--> ¼Ò¸ðµÈ »ê¼Ò¾ç ¸¸Å­ ¿ë±â³»ÀÇ »ê¼Ò ¾Ð·ÂÀÌ °¨¼ÒµÇ¹Ç·Î
--> »ê¼Ò ¾Ð·ÂÀÇ º¯È­¸¦ ÃøÁ¤ÇÏ¿©
--> ÀÚµ¿À¸·Î BOD °ª (mg/l, ppm) À¸·Î ȯ»êÇÏ¿© ³ªÅ¸³»ÁÖ´Â ¹æ½Ä
Manometric Method ´Â °øÀÎµÈ BOD ºÐ¼® ±â¹ýÀ¸·Î¼­ Àü¼¼°è¿¡¼­ ³Î¸® »ç¿ëµÇ°í ÀÖ½À´Ï´Ù.
BOD Incubator ÀÇ ¹®À» ¿­°í ´Ý´Â ºÒÆíÇÔÀÌ ¾øÀÌ ¿ë±â³» BOD °ªÀ» PC ¸¦ ÅëÇØ ½Ç½Ã°£À¸·Î È®ÀÎ °¡´ÉÇÑ ¸ðµ¨
BOD °ªÀÌ ½Ç½Ã°£À¸·Î BOD Sensor ³ªÅ¸³ª¹Ç·Î BOD °ªÀÇ º¯È­·®À» Áö¼ÓÀûÀ¸·Î È®ÀÎ °¡´É
carbonaceous oxidation Áï À¯±â¹°ÁúÀÇ »êÈ­¿¡ ÀÇÇÑ »ê¼Ò¼Ò¸ð·®¸¸ Á¤È®ÇÏ°Ô ÃøÁ¤. :: ammonia oxidation °°Àº ¹«±â¹° »êÈ­´Â ¾ïÁ¦µÊ
¿ëÁ¸»ê¼ÒÀÇ »ê¼Ò¼Ò¸ð·®¿¡ ÀÇÇÑ BOD °ªÀ» º°µµ·Î °è»êÇÔÀÌ ¾øÀÌ BOD °ªÀÌ mg/l, ppm ´ÜÀ§·Î Á÷Á¢ÀûÀ¸·Î PC ¿¡ Ç¥½ÃµÊ
Very Easy To Handle, Very Quick, Very Easy to Read
BOD EVO Sensor System 6
- 6°³ ¶Ç´Â 10°³ÀÇ sample ÀÇ BOD ¸¦ µ¿½Ã¿¡ ÃøÁ¤ÇÏ´Â Àåºñ
- Wireless Data Transferring Sensor
- includes
    * 6,10x BOD Sensor
    * 6,10x 300ml dark glass bottle
    * 6,10x Alkali Holder : ¿ë±â³» CO2 Á¦°Å¿ë
    * 6,10x Stirring Bar
    * 6- or 10-position stirring station
BOD Wireless DataBox
- BOD EVO Sensor ·Î ºÎÅÍ Àü¼ÛµÇ´Â BOD °ªÀ» PC ÀÇ BODSoft
  ÇÁ·Î±×·¥À¸·Î Àü´ÞÇÏ´Â ±â´É
- ÃÖ±Ù ´ëºÎºÐÀÇ BOD data ¸¦ ÀÚü ÀúÀåÇÏ´Â ±â´É
- 80°³ sample ÀÇ BOD °ªÀ» ÀÚü ÀúÀåÇÏ´Â ±â´É
- BOD EVO Sensor ·Î ºÎÅÍ DataBox ·Î Àü¼ÛµÇ´Â °£°ÝÀ»
  30ºÐ¿¡¼­ 24½Ã°£ °£°Ý±îÁö ÀÚÀ¯·ÎÀÌ ¼³Á¤ °¡´É
BODSoft
- BOD ÃøÁ¤ °ªÀÌ ½Ç½Ã°£À¸·Î display
- battery ÀÇ »óŵîÀ» Æ÷ÇÔÇÏ´Â ¸ðµç BOD °ü·Ã Á¤º¸µéÀÌ display
- ±×·¡ÇÁ, Å×ÀÌºí µî ´Ù¾çÇÑ ÇüÅ·Πǥ½Ã
- xls, txt, csv ÀÇ ÇüÅ·ΠÅ×½ºÆ® °á°ú¸¦ Á¤¸® °¡´É


Specifications
Real Time Data Reading (mg/l, ppm) On display
PC Data Reading (mg/l, ppm) Yes
Data Storage BOD5 : Every 30 min/1/2/4/6/8/12/24 hours
BODultimate : Every 2/4/6/8/12/24 hours
Scales (ppm BOD) 90, 250, 600, 999
Dimensions (WxHxD, mm) 270 x 300 x 175
Weight (kg) 2.3



 