MicroPette Plus Single Channel Micropipette |
|
|
MicroPette Plus Multi Channel Micropipette |
|
|
Cat. No. |
|
MicroPette Plus Micropipette |
°ßÀû¿äû |
|
|
121¡É ¿¡¼ ÁøÇàµÇ´Â autoclave ¸¦ ¿Ïº®ÇÏ°Ô Áö¿ø |
|
|
ÀÎü°øÇÐÀû ¼³°è¸¦ ¹ÙÅÁÀ¸·Î Á¦ÀÛµÇ¾î ±×¸³°¨ÀÌ Å¹¿ù |
|
|
¿À·§µ¿¾È »ç¿ëÇÏ¿©µµ ¼Õ°ú ¼Õ¸ñ¿¡ ÇǷΰ¨ÀÌ ¸Å¿ì Àû´Ù. |
|
|
¿ë·® ÀбⰡ ¸Å¿ì ½±´Ù. |
|
|
´©±¸³ª ½±°Ô ÇÒ ¼ö ÀÖ´Â calibration |
|
|
ISO8655 ¿¡ ÀÇ°Å ¸ðµç MicroPette Á¦Ç°¿¡´Â °¢°¢ÀÇ calibration certificate Á¦°ø |
|
|
¿Â¶óÀÎ calibration °¡´É |
|
|
0.1§¡ ¿¡¼ 5ml ¹üÀ§±îÁö »ç¿ëÇÒ ¼ö ÀÖ´Â ´Ù¾çÇÑ volume range ÀÇ MicoPette °ø±Þ |
|
<
Cat. No. |
|
MicroPette Plus 8-channel Micropipette |
°ßÀû¿äû |
|
MicroPette Plus 12-channel Micropipette |
°ßÀû¿äû |
|
|
Single-channel Micropipette ÀÇ Æ¯Â¡À» ±×´ë·Î °¡Áü |
|
|
8-channel micropipette °ú 12-channel micropipette |
|
|
dispensinh head °¡ ȸÀüÇÏ´Â ±¸Á¶·Î µÇ¾î »ç¿ëÀÌ Æí¸® |
|
|
piston °ú tip cone ÀÌ °³º°À¸·Î ÀÛµ¿ÇÏ´Â ±¸Á¶·Î µÇ¾î À¯Áö º¸¼ö°¡ Æí¸® |
|
|
tip À» ¼³Ä¡ÇÏ´Â tip cone Àº °í°µµ ¹°Áú·Î ÀÌ·ç¾îÁ® high sealing performance |
|
|
»ó¾÷ÀûÀ¸·Î °ø±ÞµÇ´Â ´ëºÎºÐÀÇ tip °ú ȣȯÇÏ¿© »ç¿ë |
|
|
¿Â¶óÀÎ calibration °¡´É |
|
|
Single-channel Adjustable Volume Pipettes |
Volume Range ul |
Increment ul |
Test Volume ul |
Error Limits in Accordance to ISO8655-2 |
Accuracy Error |
Precision Error |
% |
ul |
% |
ul |
0.1 - 2.5 |
0.05 |
2.5 |
2.50 |
0.0625 |
2.00 |
0.05 |
1.25 |
3.00 |
0.0375 |
3.00 |
0.0375 |
0.25 |
12.00 |
0.03 |
6.00 |
0.015 |
0.5 - 10 |
0.1 |
10 |
1.00 |
0.1 |
0.80 |
0.08 |
5 |
1.50 |
0.075 |
1.50 |
0.075 |
1 |
2.50 |
0.025 |
1.50 |
0.015 |
2 - 20 |
0.5 |
20 |
0.90 |
0.18 |
0.40 |
0.08 |
10 |
1.20 |
0.12 |
1.00 |
0.1 |
2 |
3.00 |
0.06 |
2.00 |
0.04 |
5 - 50 |
0.5 |
50 |
0.60 |
0.3 |
0.30 |
0.15 |
25 |
0.90 |
0.225 |
0.60 |
0.15 |
5 |
2.00 |
0.1 |
2.00 |
0.1 |
10 - 100 |
1 |
100 |
0.80 |
0.8 |
0.15 |
0.15 |
50 |
1.00 |
0.5 |
0.40 |
0.2 |
10 |
3.00 |
0.3 |
1.50 |
0.15 |
20 - 200 |
1 |
200 |
0.60 |
1.2 |
0.15 |
0.3 |
100 |
0.80 |
0.8 |
0.30 |
0.3 |
20 |
3.00 |
0.6 |
1.00 |
0.2 |
50 - 200 |
1 |
200 |
0.60 |
1.2 |
0.15 |
0.3 |
100 |
0.80 |
0.8 |
0.30 |
0.3 |
50 |
1.00 |
0.5 |
0.40 |
0.2 |
100 - 1000 |
5 |
1000 |
0.60 |
6 |
0.20 |
2 |
500 |
0.70 |
3.5 |
0.25 |
1.25 |
100 |
2.00 |
2 |
0.70 |
0.7 |
200 - 1000 |
5 |
1000 |
0.60 |
6 |
0.20 |
2 |
500 |
0.70 |
3.5 |
0.25 |
1.25 |
200 |
0.90 |
1.8 |
0.30 |
0.6 |
1000 - 5000 |
50 |
5000 |
0.50 |
25 |
0.15 |
7.5 |
2500 |
0.60 |
15 |
0.30 |
7.5 |
1000 |
0.70 |
7 |
0.30 |
3 |
2 - 10 ml |
0.1 ml |
10 ml |
0.60 |
60 |
0.20 |
20 |
5 ml |
1.20 |
60 |
0.30 |
15 |
2 ml |
3.00 |
60 |
0.60 |
12 |
8-channel Adjustable Volume Pipettes |
Volume Range ul |
Increment ul |
Test Volume ul |
Error Limits in Accordance to ISO8655-2 |
Accuracy Error |
Precision Error |
% |
ul |
% |
ul |
0.5 - 10 |
0.1 |
10 |
1.50 |
0.15 |
1.50 |
0.15 |
5 |
2.50 |
0.125 |
2.50 |
0.125 |
1 |
4.00 |
0.04 |
4.00 |
0.04 |
5 - 50 |
0.5 |
50 |
1.00 |
0.5 |
0.50 |
0.25 |
25 |
1.50 |
0.375 |
1.00 |
0.25 |
5 |
3.00 |
0.15 |
2.00 |
0.1 |
50 - 300 |
5 |
300 |
0.70 |
2.1 |
0.25 |
0.75 |
150 |
1.00 |
1.5 |
0.50 |
0.75 |
50 |
1.50 |
0.75 |
0.80 |
0.4 |
12-channel Adjustable Volume Pipettes |
Volume Range ul |
Increment ul |
Test Volume ul |
Error Limits in Accordance to ISO8655-2 |
Accuracy Error |
Precision Error |
% |
ul |
% |
ul |
0.5 - 10 |
0.1 |
10 |
1.50 |
0.15 |
1.50 |
0.15 |
5 |
2.50 |
0.125 |
2.50 |
0.125 |
1 |
4.00 |
0.04 |
4.00 |
0.04 |
5 - 50 |
0.5 |
50 |
1.00 |
0.5 |
0.50 |
0.25 |
25 |
1.50 |
0.375 |
1.00 |
0.25 |
5 |
3.00 |
0.15 |
2.00 |
0.1 |
50 - 300 |
5 |
300 |
0.70 |
2.1 |
0.25 |
0.75 |
150 |
1.00 |
1.5 |
0.50 |
0.75 |
50 |
1.50 |
0.75 |
0.80 |
0.4 |
|