DS-36D High Precision Benchtop Spectrophotometer
Dual Optical Path Design with Differential Spectrum Engine and Nanoscale Grating
DS-36D Benchtop Spectrophotometer
DS-36D Benchtop Spectrophotometer
Dual Optical Path Design
Differential Spectrum Engine
Innovative 1nm Resolution Grating
Excellent Inter-Instrument Consistency
Long-term Repeatability Curve at Constant Temperature
Inter-temperature Repeatability and Stability Curve
Fluorescence Calibration Technique
High Resolution Preview Camera
Cat. No.
DS-36D Benchtop Spectrophotometer
Á¦Ç°¹®ÀÇ
¡á
¼¼°è ÃÖ°í ¼öÁØÀÇ ±â±â°£ ÃøÁ¤ °á°ú ÀÏÄ¡¼º (Inter-Instrument Consistency)
DS-36D ¸ðµ¨ÀÇ ±â±â°£ ÃøÁ¤°á°ú ÀÏÄ¡¼ºÀº °¡Àå Å« ÃøÁ¤ Aperture ÀÎ XLAV ¥Õ25.4mm/¥Õ30mm ¸¦ »ç¿ëÇÏ¿´À» ¶§
¥ÄE*ab (»öÂ÷°ª Ç¥ÁØÆíÂ÷) °ªÀÌ 0.15 ·Î¼ ¼¼°è ÃÖ°í ¼öÁØÀ» ÀÚ¶ûÇÕ´Ï´Ù.
ÀÌ´Â DS-35 High Precision Benchtop Spectrophotometer °¡ ¼¼°è ÃÖ°í ¼öÁØÀÇ High-End ±Þ Color Measurement Àåºñ¶ó´Â °ÍÀ» ÀǹÌÇÕ´Ï´Ù.
¡á
Ź¿ùÇÑ ÃøÁ¤ °á°ú ÀçÇö¼º (Repeatability)
ÇϳªÀÇ DS-36D ¸ðµ¨À» ÀÌ¿ëÇÏ¿© µ¿ÀÏÇÑ »ùÇÃÀ» ¿©·¯ ¹ø ÃøÁ¤ÇÏ¿´À» ¶§ÀÇ °á°ú°ª ¥ÄE*ab (»öÂ÷°ª Ç¥ÁØÆíÂ÷) ´Â 0.01 ÀÌÇÏÀÔ´Ï´Ù.
ÀÌ ¼öÄ¡´Â Çö´ë ºÐ±¤ÇÐ ±â¼ú¿¡¼ ÃÖ»óÀ§ µî±Þ (High-End) Àåºñ¸¸ÀÌ µµ´ÞÇÒ ¼ö ÀÖ´Â ¼öÄ¡ÀÔ´Ï´Ù. À°¾ÈÀ¸·Î ½Äº° °¡´ÉÇÑ »öÂ÷ÀÇ ÇѰ谡 º¸Åë 0.5~1.0 ÀÓÀ» °¨¾ÈÇϸé,
±â°èÀû ³ëÀÌÁî°¡ °ÅÀÇ ¾ø´Â ¿Ïº®¿¡ °¡±î¿î »óŸ¦ ÀǹÌÇÕ´Ï´Ù.
¡á
°íµµ·Î Á¤¹ÐÇÑ ºÐ±¤ ¹Ý»çÀ²/Åõ°úÀ²
ÀÌ ÀåºñÀÇ ±¤¿ø¿¡¼ ³ª¿À´Â ºûÀÇ ºÐ±¤ ¹Ý»çÀ²/Åõ°úÀ² (Spectral reflection / transmittance) ÀÇ ÀçÇö¼º (Repeatability) Àº 0.1% ÀÌÇϷμ
ÀÌ´Â ÀÌ Àåºñ´Â ¸Å¿ì ¹Î°¨ÇÏ°í ¾ÈÁ¤ÀûÀÎ ¼¾¼¸¦ žÀçÇÏ¿©, ¾ðÁ¦ ÃøÁ¤ÇÏ´õ¶óµµ °ÅÀÇ ¿Ïº®ÇÏ°Ô µ¿ÀÏÇÑ °á°ú°ªÀ» º¸ÀåÇÑ´Ù´Â °ÍÀ» ÀǹÌÇÕ´Ï´Ù.
¡á
Dual Optical Path ¼³°è
±¤¿ø¿¡¼ ³ª¿À´Â ºûÀº µÎ °¥·¡ Path ·Î ³ª´µ¾î ÁøÇàÇÕ´Ï´Ù.
•
Sample Path (»ùÇñ¤) : ±¤¿øÀÇ ºûÀÌ ÀûºÐ±¸(Integrating Sphere) ³»ºÎ¿¡¼ È®»êµÇ¾î »ùÇà ǥ¸é¿¡ ¹Ý»çµÈ ÈÄ,
½½¸´°ú ·»Áî, ±×¸®°í ȸÀý°ÝÀÚ (Diffraction Grating) ¸¦ °ÅÃÄ ¼¾¼·Î µé¾î°¡´Â °æ·ÎÀÔ´Ï´Ù. ¢¡ ½ÇÁ¦ »ùÇÃÀÇ »ö»ó Á¤º¸¸¦ ´ã°í ÀÖ½À´Ï´Ù.
•
Reference Path (ÂüÁ¶±¤) : »ùÇÃÀÌ ÀÖ´Â ÀûºÐ±¸¸¦ °ÅÄ¡Áö ¾Ê°í ±¤¿øÀÇ ºûÀ» ½½¸´°ú ·»Áî, ±×¸®°í ȸÀý°ÝÀÚ (Diffraction Grating) ¸¦ °ÅÃÄ
º°µµÀÇ ¼¾¼·Î º¸³»´Â °æ·ÎÀÔ´Ï´Ù.
¢¡ ÇöÀç ±¤¿øÀÇ »óÅ (¹à±â, ÆÄÀåºÐÆ÷ µî) ¸¦ ½Ç½Ã°£ ÆÄ¾ÇÇÕ´Ï´Ù.
ÂüÁ¶±¤°ú »ùÇñ¤À» Áö¼ÓÀûÀ¸·Î ºñ±³ÇÏ¿©, ¿¹¸¦µé¾î Àü¾ÐÀÌ ¾àÇØÁ® ºûÀÇ ¼¼±â°¡ ¹Ì¼¼ÇÏ°Ô ¾àÇØÁö¸é Àåºñ´Â À̸¦ °¨ÁöÇÏ¿© »ùÇñ¤ÀÇ ºûÀÇ ¼¼±â¸¦ ÀÚµ¿À¸·Î Á¶ÀýÇÏ¿©
Á¤È®ÇÑ ÃøÁ¤ÀÌ ÀÌ·ç¾îÁö°Ô ÇÕ´Ï´Ù.
¡á
Differential Spectrum Engine
ÀÌ ¿£ÁøÀº µÎ °³ÀÇ ±¤ÇÐ °æ·Î¸¦ Åë°úÇÑ ÂüÁ¶±¤°ú »ùÇñ¤ µÎ ½ÅÈ£¸¦ ´ëÁ¶ÇÏ¿© »ùÇÃÀÇ ½ÇÁ¦ÀûÀÎ »ö»ó ½ºÆåÆ®À¸·Î º¸Á¤ÇÏ¿©ÁÖ´Â ½Ã½ºÅÛÀÔ´Ï´Ù.
Áï, Dual Optical Path ¸¦ ÅëÇØ ÂüÁ¶±¤°ú »ùÇñ¤Àº
¨ç ¿À¸ñȸÀý°ÝÀÚ (Concave Diffraction Grating) ¿¡¼ ºÐ±¤µÇ¾î
¨è ·»Á Áö³ª °¢°¢ÀÇ ¼¾¼·Î µµ´ÞÇÏ°Ô µÇ°í
¨é Àåºñ ¸Þ¸ð¸®¿¡ ÀúÀåµÈ Ç¥ÁØ ±¤¿ø½ºÆåÆ®·³°ú ÂüÁ¶±¤À» ºñ±³ÇÏ¿©
¨ê ½ºÆåÆ®·³¿¡ Â÷À̰¡ ÀÖÀ¸¸é
¨ë »ùÇñ¤ÀÇ ½ºÆåÆ®·³À» º¸Á¤ÇÏ¿©ÁØ´Ù.
¡á
Dual Optical Path + Differential Spectrum Engine ÀåÁ¡
Dual Optical Path ¼³°è¿Í Differential Spectrum Engine º¸Á¤½Ã½ºÅÛÀ» °®Ãá DS-36D ¸ðµ¨Àº ´ÙÀ½°ú °°Àº
Çõ½ÅÀûÀΠƯ¡À» °¡Áý´Ï´Ù.
•
Extremly High Repeatibility
: ȯ°æ º¯È (¿Âµµ, ½Àµµ) ³ª ±¤¿øÀÇ ³ëÈÄÈ·Î ÀÎÇÑ ¹Ì¼¼ÇÑ Ãâ·Â º¯È¸¦ Áï°¢ º¸Á¤ÇϹǷÎ, µ¿ÀÏÇÑ »ùÇÃÀ» ¿©·¯ ¹ø ÃøÁ¤ÇßÀ» ¶§
¥ÄE*ab (»öÂ÷°ª Ç¥ÁØÆíÂ÷) °ªÀÌ 0.01 ·Î¼ ¼¼°è ÃÖ°í ¼öÁØÀÇ ÀçÇö¼ºÀ» °¡Áý´Ï´Ù.
•
Inter-instrument Consistency
: ¿©·¯ ´ëÀÇ DS-36D Àåºñ¸¦ ¿î¿ëÇÒ ¶§, °¢ ÀåºñÀÇ ±¤¿ø »óŰ¡ Á¶±Ý¾¿ ´Ù¸£´õ¶óµµ ÂüÁ¶ °æ·Î¸¦ ÅëÇØ Ç¥ÁØÈµÈ °ªÀ» »êÃâÇϹǷÎ
Àåºñ °£ ¥ÄE*ab (»öÂ÷°ª Ç¥ÁØÆíÂ÷) °ªÀÌ 0.15 ·Î¼ ¸Å¿ì ³ôÀº µ¥ÀÌÅÍ È£È¯¼ºÀ» °¡Áý´Ï´Ù.
•
Long Term Stability
: Àåºñ¸¦ ¿À·¡ ÄÑµÎ¸é ¿ÀÌ ¹ß»ýÇØ ±¤Çа迡 ¹Ì¼¼ÇÑ º¯ÇüÀÌ ¿Ã ¼ö Àִµ¥, ÀÌÁß °æ·Î ¼³°è´Â À̸¦ ½Ç½Ã°£À¸·Î °¨½ÃÇϹǷΠÀæÀº
Calibration ¾øÀ̵µ ¾ÈÁ¤ÀûÀÎ µ¥ÀÌÅ͸¦ À¯ÁöÇÕ´Ï´Ù.
¡á
1nm ºÐÇØ´ÉÀ» °¡Áø ȸÀý°ÝÀÚÀÇ Çõ½ÅÀûÀÎ ±¤Çбâ¼ú
ÀÔ»çµÇ´Â ºûÀ» ¹«Áö°³ ÇüÅ·ΠÆîÃÄÁִ ȸÀý°ÝÀÚ (Diffraction Grating) ÀÇ wavelength resolution (ÆÄÀå ºÐÇØ´É) Àº ÀϹÝÀûÀ¸·Î ¾à 10nm Á¤µµÀÎ ¹Ý¸é DS-36D °¡ ÀåÂøÇÑ È¸Àý°ÝÀÚÀÇ ÆÄÀå ºÐÇØ´ÉÀº
1nm ÀÔ´Ï´Ù. ÀÌ´Â DS-36D ¿¡´Â ¼ö¹é °³ÀÇ Çȼ¿·Î ÀÌ·ç¾îÁø ±¤¼¾¼¿Í ÇÔ²² 1nm Â÷ÀÌÀÇ ¾ÆÁÖ ¹Ì¼¼ÇÑ »ö º¯È±îÁöµµ ¹°¸®ÀûÀ¸·Î ºÐ¸®Çس¾ ¼ö ÀÖ´Â ÃʰíÁ¤¹Ð ±¤Çбâ¼úÀÌ Àû¿ëµÇ¾ú´Ù´Â °ÍÀ» ÀǹÌÇÕ´Ï´Ù.
•
ÃÊÁ¤¹Ð µ¥ÀÌÅÍ (High Fidelity)
: ºûÀÇ ½ºÆåÆ®·³ °î¼±ÀÌ ¸Å¿ì ¸Å²ô·´°Ô ÃßÃâµË´Ï´Ù. À̴ ƯÈ÷ »ö º¯È°¡ ±Þ°ÝÇÑ Æ¯Á¤ ±¸°£ (¿¹: ¼±¸íÇÑ »¡°£»öÀ̳ª Ư¼ö ¾È·á) ¿¡¼
À» Á¤È®È÷ Àâ¾Æ³»´Â ¿øµ¿·ÂÀÌ µË´Ï´Ù
•
³·Àº ±â±â °£ ÆíÂ÷ (Inter-Instrument Consistency)
: Çϵå¿þ¾î°¡ 1nm ±ÞÀ¸·Î Á¤¹ÐÇÏ°Ô ¼¼ÆÃµÇ¾î Àֱ⠶§¹®¿¡, µ¿ÀÏÇÑ ¸ðµ¨ÀÇ ´Ù¸¥ Àåºñ¿Í ÃøÁ¤°ªÀ» ºñ±³Çصµ ¥ÄE*ab (»öÂ÷°ª Ç¥ÁØÆíÂ÷) °ªÀÌ 0.15 ÀÌÇϷμ
±â±â°£ ÆíÂ÷°¡ ¸Å¿ì Àû½À´Ï´Ù.
•
º¹ÀâÇÑ Á¶»ö (Matching) ¿¡ À¯¸®
: ¹Ì¼¼ÇÑ ÆÄÀåÀÇ º¯µ¿À» °¨ÁöÇÒ ¼ö ÀÖÀ¸¹Ç·Î, Color Matching Software ¿Í ¿¬µ¿Çϸé ÈξÀ ´õ Á¤È®ÇÑ À×Å© ¹èÇÕ ·¹½ÃÇǸ¦ ¾òÀ» ¼ö ÀÖ½À´Ï´Ù
¡á
High Precision Automatic Calibration (°íÁ¤¹Ð ÀÚµ¿ º¸Á¤)
DS-36D ¸ðµ¨ÀÇ Áö´ÉÇü Automatic Calibration ±â´ÉÀº ½Ã°£°ú Àå¼Ò(¿Âµµ) ¿¡ ±¸¾Ö¹ÞÁö ¾Ê´Â Àý´ëÀûÀÎ µ¥ÀÌÅÍ ÀçÇö¼ºÀ» ½ÇÇöÇØ ÁÖ´Â ÇÙ½É ÀåÄ¡ÀÔ´Ï´Ù
•
Long-term Repeatability curve at constant temperature
ÀϹÝÀûÀÎ Àåºñ´Â ±¤¿øÀÇ ³ëȳª ³»ºÎ ȸ·ÎÀÇ ¹Ì¼¼ÇÑ º¯È·Î ÀÎÇØ ½Ã°£ÀÌ Áö³¯¼ö·Ï ÃøÁ¤°ªÀÇ ¿ÀÂ÷ (¥ÄE*ab) °¡ Ä¿Áý´Ï´Ù.
±×·¯³ª DS-36D ´Â ÀÚµ¿ º¸Á¤ ±â¼úÀ» ÅëÇØ 3,600½Ã°£ (¾à 5°³¿ù) ÀÌ Áö³ªµµ ¹Ýº¹ Á¤¹Ðµµ¸¦ 0.01 ¼öÁØÀ¸·Î ÀÏÁ¤ÇÏ°Ô À¯ÁöÇÕ´Ï´Ù. (ÃÊ·Ï»ö ¼±)
•
Inter-temperature Repeatability and Stability Curve
ÀϹÝÀûÀÎ Àåºñ´Â ÁÖº¯ ¿Âµµ (25¡É ¡æ 40¡É ¡æ 0¡É µî) °¡ º¯ÇÏ¸é ³»ºÎ ±¤Çа谡 ¹Ì¼¼ÇÏ°Ô ÆØÃ¢/¼öÃàÇÏ¸ç µ¥ÀÌÅͰ¡ ½ÉÇÏ°Ô ¿äµ¿Ä¨´Ï´Ù.
(ȸ»ö ¼±: Ÿ»ç ºê·£µåÀÇ Å« ¿ÀÂ÷). ±×·¯³ª DS-36D ´Â ¿Âµµ°¡ ±Þ°ÝÈ÷ º¯Çصµ ¥ÄE*ab °ªÀÌ °ÅÀÇ 0.05 ÀÌÇÏ¿¡¼ ¸Ó¹´´Ï´Ù.
ÀÌ´Â ³Ã¹æÀÌ Àß ¾È µÇ´Â °øÀåÀ̳ª °Ü¿ïö Ãß¿î â°í µî ¿¾ÇÇÑ ÇöÀå ȯ°æ¿¡¼µµ ½ÇÇè½Ç ¼öÁØÀÇ Á¤È®ÇÑ ÃøÁ¤ÀÌ °¡´ÉÇÔÀ» º¸¿©ÁÝ´Ï´Ù.
¡á
Fluorescence Calibration Technique (Çü±¤ º¸Á¤ ±â¼ú)
Çü±¤ Áõ¹éÁ¦´Â Àڿܼ±(UV) ¿¡³ÊÁö¸¦ Èí¼öÇÏ¿© °¡½Ã±¤¼± ¿µ¿ª (º¸Åë Ǫ¸¥»ö ´ë¿ª) ÀÇ ºûÀ¸·Î ¹æÃâÇÕ´Ï´Ù.
º¸Á¤ ±â¼úÀÌ ¾ø´Â ÀϹÝÀûÀÎ Àåºñ´Â ½Ã°£ÀÌ Áö³ª¸é¼ ±¤¿ø ¼ÓÀÇ UV ¿¡³ÊÁö°¡ ¾àÇØÁö°Å³ª º¯ÇÏ°Ô µÇ¾î ½ÇÁ¦ »ùÇÃÀÌ °¡Áø Çü±¤ ¹ÝÀÀÀ» Á¦´ë·Î ²ø¾î³»Áö ¸øÇØ
½ÇÁ¦º¸´Ù ´ú ÇϾé°Ô (³ë¶þ°Ô) ÃøÁ¤µÇ´Â ¿À·ù°¡ ¹ß»ýÇÕ´Ï´Ù.
DS-36D ´Â CHNSpec »ç°¡ ÀÚü °³¹ßÇÑ Fluorescence Calibration Technique À» ÀÌ¿ëÇÏ¿© ±¤¿øÀÇ UV »óŰ¡ º¯ÇÏ¿©µµ Çü±¤ ½Ã·áÀÇ »ö»óÀ» ±âÁØ Ç¥Áع°°ú ¶È°°ÀÌ (¿ÀÂ÷ ¾øÀÌ) ÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù.
¡á
°íÇØ»óµµ Preview Camera
°íÇØ»óµµ Ä«¸Þ¶ó¸¦ ÀåÂøÇÑ DS-36D ´Â ¾ÆÁÖ ÀÛÀº »ùÇÃÀ̳ª º¹ÀâÇÑ ¹®¾çÀÌ ÀÖ´Â ½Ã·áµµ ½Ç¼ö ¾øÀÌ Á¤¹ÐÇÏ°Ô Á¶ÁØÇÏ¿© ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
•
Á¤¹ÐÇÑ Å¸°ÙÆÃ :
ÃøÁ¤ÇÏ·Á´Â »ùÇÿ¡ ¹«´Ì°¡ Àְųª ·Î°í, ÅØ½ºÆ®°¡ ÀÖ´Â °æ¿ì, Ä«¸Þ¶ó°¡ È帴ÇÏ¸é ¿øÇÏÁö ¾Ê´Â ºÎºÐ (¿¹: ±ÛÀÚ Å׵θ®) ±îÁö ÃøÁ¤µÇ¾î ¿ÀÂ÷°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.
DS-36D´Â ¼±¸íÇÑ È¸éÀ» ÅëÇØ Á¤È®È÷ ÃøÁ¤ÇϰíÀÚ ÇÏ´Â ÁöÁ¡¸¸ Á¶ÁØÇÒ ¼ö ÀÖ°Ô ÇØÁÝ´Ï´Ù.
•
ºÒ·® ¿©ºÎ »çÀü È®ÀÎ :
ÃøÁ¤ Àü¿¡ »ùÇà ǥ¸é¿¡ ¹Ì¼¼ÇÑ ¸ÕÁö³ª ½ºÅ©·¡Ä¡°¡ ÀÖ´ÂÁö Ä«¸Þ¶ó·Î ¹Ì¸® È®ÀÎÇÒ ¼ö ÀÖ¾î, À߸øµÈ µ¥ÀÌÅÍ ¼öÁýÀ» ¹æÁöÇÕ´Ï´Ù.
•
»ç¿ëÀÚ ÆíÀǼº :
¿À¸¥ÂÊ È¸é ÇÏ´ÜÀ» º¸¸é '¹à±â ±³Á¤' À̳ª »ö»ó Åæ Á¶Àý ¿É¼ÇÀÌ ÀÖ¾î, »ùÇÃÀÇ ¹à±â¿¡ µû¶ó ÃÖÀûÈµÈ È¸éÀ¸·Î °üÂûÇÒ ¼ö ÀÖ½À´Ï´Ù.
VIDEO
CHNSpec new Benchtop Spectrophotometer DS-36D
VIDEO
Demonstration of measuring paint test cards with the Desktop Spectrophotometer DS-36D
VIDEO
Operation Video of Desktop Spectrophotometer DS-36D
DS-36D High Precision Benchtop Spectrophotometer Technical Data
Lighting / Measuring Conditions
Reflection£ºd/8£¨diffuse illumination£¬8¡Ædirection reception£©
SCI£¨Contains specular reflected light£©/ SCE£¨not contain specular reflected light£©measure at same time.
Compliance standards£ºCIE No.15¡¢GB/T 3978¡¢GB 2893¡¢GB/T 18833¡¢ISO7724/1¡¢DIN5033 Teil7¡¢
JIS Z8722 Condition C¡¢ASTM E1164¡¢ASTM-D1003-07
Transmission£ºd/0£¨diffuse illumination, vertical reception£©
Sensor
Differential Spectrum Engine
Spectroscopic Method
Concave grating
Integrating Sphere Diameter
152mm
Wavelength Range
360nm-780nm
Wavelength Interval
10nm
Reflectance Measurement Range
0-200%, Resolution 0.01%
Lighting Source
Pulsed Xenon Lamps & LED
Ultraviolet Measurement
Includes UV¡¢400nm cutoff¡¢420nm cutoff¡¢460nm cutoff
Measuring Time
Single Mode : < 2 sec
Lighting / Measuring Calibers
- Reflection£ºXLAV ¥Õ25.4mm/¥Õ30mm£»LAV¥Õ15mm/¥Õ18mm£»MAV¥Õ8mm/¥Õ11mm£»SAV¥Õ3mm/¥Õ6mm
- Users can customize the calibre, and the calibre switch is automatically recognized
- Transmission£º¥Õ17mm / ¥Õ25mm
Sample Dimension
Sample Height is not limited, Thickness is ¡Â50mm
Repeatability
¥ÄE*ab¡Â0.01,   Spectral reflection / transmittance ¡Â0.1%
Inter-Instrument Consistency
XLAV ¥ÄE*ab 0.15
Long-term Repeatability
XLAV chroma value:standard deviation ¥ÄE*ab within 0.01£¨under constant temperature conditions,the white correction plate is measured every hour within 24 hours)
Standard Observer
2¡Æ & 10¡Æ
Viewing Light Source
A, B, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, U35, DLF, NBF, TL83, TL84, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1,
LED-V1, LED-V2, LED-8
Language
Simplified Chinese, English, Traditional Chinese, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish
Display Content
Spectral data, Spectrogram, Chromaticity Data, Chromaticity Map, Pass/Fail Judgment, Simulation Color, Color Evaluation, Fog, Liquid Chromaticity, Color Bias
Color space
CIE LAB, CIE LUV, LCh, Hunter L¬ß, ¬Ñ¬ß, b¬ß, Yxy, XYZ, Musell, s-RGB, ¥âxy
Chroma Index
WI (ASTM E313-20, ASTM E313-73, CIE, AATCC, Hunter, Taube, Berger Stensby), YI (ASTM D1925,ASTM E313-20,ASTM E313-73),
Tint (ASTM E313-20), Isochromatic index Milm, color fastness, color changing fastness, ISO brightness, R457, A density, T density, E density, M density, APHA/Hazen/
Pt-Co ((platinum-cobalt index), Gardner (Gardner Index),Saybolt(SeibertIndex), Astm color, fog, total transmittance, covering power, force, intensity
Color Difference Formula
¥ÄE*ab, ¥ÄE*CH, ¥ÄE*uv, ¥ÄE*cmc, ¥ÄE*94, ¥ÄE*00, ¥ÄEab (Hunter), 555color tone classification
Storage Capacity
8GB
Screen Size
7-inch Capacitive Touch Screen
Operating System
Android
Power Source
DC Regulated Power Supply
Operating Temperature and Humidity
5¢¦40¡ÆC, Relative Humidity 80% (35¡ÆC) below no condensation
Storage Temperature and Humidity
-20¢¦45¡ÆC, Rrelative Humidity 80% (35¡ÆC) below no condensation
Accessories
Power Adapter, USB Cable, Transmission Fixture, Software U Disk, Black Cavity, White Board, Green Board, 30mm Aperture,
18mm Aperture, 11mm Aperture, 6mm Aperture, Support Table, Cuvette, Damping Handle
Optional Accessories
Heating Transmission Jig (including Control Circuit), Vertical Bracket, Pneumatic Jacking Rod (including Control Circuit), Small Sample Holding Accessories, Reflection Cupping Plate, Fiber Test Box,
Micro Transmission Jig, Rod Box, European Standard Plug, American Atandard Plug
Port
RS-232¡¢USB¡¢USB-B¡¢Bluetooth
Camera Positioning
Ultra HD Camera£¨1400dpi£©
Automatic Calibration
Can greatly improve the Long-Term Repeatability of the instrument
Fluorescence Calibration
Can automatically adjustthe UV Intensity£¬and ensure that the value of the Instrument is highly consistent with that of other imported instruments when measuring materials containing fluorescence
Brightness Calibration
Through the Brightness Calibration Algorithm, the Real Color of Ultra-dark Samples is restored
Others
The instrument can be measured sideways,up and down (using accessories); Automatic temperatureand humidity compensation function; PC side software save sample image function