Automatic Anaerobic Chamber
Automatic Anaerobic Chamber Touch Screen
Programmable Heating Control System
Drying System
Cat. No.
857, Automatic Anaerobic Chamber °ßÀû¿äû

»ê¼Ò°¡ ¾ø´Â(Anaerobic) »óÅÂÀÇ È¯°æÀ» Á¶¼ºÇÏ¿© ÁÖ´Â Glove Box ·Î¼­ Çø±â¼º ¹Ì»ý¹° ¹è¾ç, »ê¼Ò°¡ ´êÀ¸¸é Æø¹ß¼ºÀ» ³ªÅ¸³»´Â È­ÇÐ ¹ÝÀÀ µîÀÇ ½ÇÇè¿¡ »ç¿ëµÈ´Ù.

Ãʱ⿡ Chamber ³» »ê¼Ò°¡ ¾ø´Â Çø±â¼º Á¶°ÇÀ» ¼³Á¤ÇÒ ¶§ ¸ðµç °úÁ¤ÀÌ ÀÚµ¿À¸·Î ÁøÇàµÇ´Â automatic type ÀÇ Anaerobic Chamber

»ê¼Ò°¡ ¾ø´Â Çø±â¼º Á¶°Ç ±¸Çö ¿ø¸®
Catalyst Heater (800-Heater) °¡ chamber ³»ºÎÀÇ °ø±â¸¦ ÈíÀÔÇÏ¿© °ø±âÁßÀÇ »ê¼Ò¸¦ ¹°·Î ȯ¿ø½ÃÄÑ ¼öÁõ±â »óÅ·Πchamber ·Î º¸³»°í Drying Train Canister ¿¡ ÀÖ´Â Èí½ÀÁ¦ÀÎ Molecular Sieve¢â °¡ ÀÌ ¼öºÐÀ» Á¦°ÅÇÏ°Ô µÇ¸é »ê¼Ò°¡ °ÅÀÇ ¾ø´Â Çø±â¼º »óÅÂÀÇ È¯°æÀÌ µÈ´Ù.


chamber ³» Çø±â¼º Á¶°ÇÀ» ÀÚµ¿À¸·Î Á¶¼º
O2 sensor °¡ ÀÖ¾î Á¤¹ÐÇÑ Çø±â¼º Á¶°Ç À¯Áö
10 ppm ÀÌÇÏÀÇ »ê¼Ò ³óµµ·Î Çø±â¼º »óÅ À¯Áö
Touch Screen ¿¡ ÀÖ´Â GO ANAEROBIN ¹öÆ°À» ´©¸£¸é Àü °úÁ¤ÀÌ ÀÚµ¿À¸·Î ÀÌ·ç¾î Áü
»ê¼Ò³óµµ¿Í chamber ³»ºÎ ¾Ð·ÂÀÌ ´ëÇüÀÇ Ä®¶ó Display ¿¡ Ç¥½Ã
main chamber ¿Í transfer chamber ¸ðµÎ Çø±â¼º Á¶°Ç À¯Áö
chamber ³»ºÎÀÇ ½Àµµ¿Í ¿Âµµµµ Ç¥½Ã
chamber ³»ºÎÀÇ ½Àµµ¸¦ Á¦°ÅÇÏ´Â 3°³ÀÇ Drying Train canisters
»ê¼Ò¸¦ Á¦°ÅÇÏ°í ¿Âµµ¸¦ Á¶ÀýÇÏ¿©ÁÖ´Â Programmable Catalyst Heater Unit.
chamber ³»ºÎÀÇ °¢ ¸ð¼­¸®°¡ round ÇüÅ·ΠµÇ¾î û¼Ò°¡ ¿ëÀÌÇÏ¿© µ¶¼º¹°Áú°ú À¯Çع̻ý¹°ÀÇ ¹ø½ÄÀ» ¹æÁö
Çöó½ºÆ½ ÀçÁú·Î µÈ »ó.ÇÏ µÎ°³ÀÇ section À¸·Î ±¸¼º
°¢ section Àº 9.5mm ÀÇ µÎ²¨¿î Çöó½ºÆ½ ÀçÁú·Î µÇ¾î °­ÇÑ ¿ÜºÎ Ãæ°Ý¿¡µµ ÆļյÇÁö ¾ÊÀ½
°¢ section Àº 9.5mm ÀÇ µÎ²¨¿î Çöó½ºÆ½ ÀçÁú·Î µÇ¾î °­ÇÑ ¿ÜºÎ Ãæ°Ý¿¡µµ ÆļյÇÁö ¾ÊÀ½
chamber ³»ºÎÀÇ Bright Light Çü±¤ ·¥ÇÁ´Â 40,000 ½Ã°£ÀÇ ¼ö¸íÀ» Guarantee
µÎ½ÖÀÇ ¾ç¼ÕÇü Glove ÀåÂøµÇ¾î µÎ¸íÀÌ µ¿½Ã¿¡ »ç¿ë °¡´É
2°³ÀÇ key cock valve °¡ ÀåÂøµÇ¾î mainchamber ³»ºÎ¸¦ ƯÁ¤ ±âü·Î purging °¡´É
Automatic Anaerobic Chamber ÀÇ ÀÏ¹Ý Æ¯Â¡Àº Basic Glove Box ¿Í µ¿ÀÏ

Specifications
Oxygen Concentration Oxygen Analyzer changes from percentage (%) to parts-per-million (ppm) when O2 levels reach <0.5%
O2 Sensor Accuracy (%) 0-100.0%, ¡¾1.0%
O2 Sensor Accuracy (ppm) 0-10,000, ¡¾1.0% FS
Gas Consumption for Anaerobic Achievement 300 Liters
Inside Dimensions 1,040 mm x 712 mm x 660 mm (w x d x h)
Outside Dimensions (includes transfer chamber) 1,400 mm x 890 mm x 965 mm (w x d x h)
Approximate Volume 489 Liters
Maximum Working Pressure 1.49 kPa (15 mbar)
Approximate Shipping Weight 112.5 kg



 