■ 10% Suspension of Germania, GeO₂, in Isopropyl Alcohol
리스트돌아가기

Industry : Chemical
Product : 10% suspension of Germania, GeO2, in isopropyl alcohol
Test Objective : Reduce germania particle size from 4-5 um to less than 1 um
Processor : M-110Y     (Microfluidizer High Shear Processor 장비보기)
Chambers : - Diamond Interaction Chamber (upstream) G10Z (87 um)
- Ceramic Auxiliary Processing Module (downstream) H30Z (200 um)
Number of passes : 1
Shear per pass : 5,800,000 sec -1
Process pressure : 23,000 psi
Particle size : - Premix : 8.301 um mean particle size [D90 = 14.469 um]
- 1 Pass : 0.502 um mean particle size [D90= 0.612 um]
Summary of results : The mean particle size of the germania was reduced from 8.301 um to 0.502 um after one pass @ 23 kpsi using the M-110Y Microfluidizer processor.