Industry : |
| |
Pharmaceutical |
| | |
Product : |
| |
Ophthalmic suspension |
| | |
Test Objective : |
| |
Reduce particle size to 0.7 um |
| | |
Processor : |
| |
M-110EH     (Microfluidizer High Shear Processor 장비보기) |
| | |
Number of passes : |
| |
35 (continous) |
| | |
Process pressure : |
| |
25,000 psi |
| | |
Mean particle size : |
| |
Premix : ~ 5 um (mean diameter) 35 process passes : 0.75 um (mean diameter) |
| | |
Summary of results : |
| |
Processing at 25,000 psi achieved the target particle size in a continous run using the M-110EH Microfluidizer materials processor